Result Summary
For units please see the headers in the result file.
All values in the result summary are integrated over the whole simulation period, thus one year.
Base results from EnergyPlus simulation output
All the following values are stated as overall values for the whole building and as specific values per m2 floor area. To convert the EnergyPlus annual output values for the whole building to specific per floor area values to floor area is retrieved from EnergyPlus outputs *.eio file.
- DHW Annual
Energy demand for domestic hot water. Corresponds to EnergyPlus output DistrictHeating:Building.
- Heating Annual
Energy demand for space heating. Corresponds to EnergyPlus output DistrictHeating:HVAC.
- Cooling Annual
Energy demand for space cooling. Corresponds to EnergyPlus output DistrictCooling:Facility.
- Electricity Annual
Electricity demand for appliances, lighting etc. Corresponds to EnergyPlus output Electricity:Facility.
By CESAR-P post-processed Cost & Emission results
Input values used to calculate cost & emission results
Energy demands: DHW Annual, Heating annual and Electricity Annual - see base results explained above.
Energy carrier: DHW Energy Carrier respectively Heating Energy Carrier specified in the input data (e.g. in your BuildingInformation.csv), for electricity the energy carrier is fixed to electricity
Simulation year: the reference year used to calculate cost & emissions (configuration SITE - SIMULATION_YEAR, defaults to 2015)
Lookup tables: different lookup tables for system efficiency, heating value, PEN, CO2 and cost factors. Factors depend on the selected Energy Strategy and simulation year (configuration ENERGY_STRATEGY - ENERGY_STRATEGY_SELECTION, defaults to “Business as usual”). For details package see cesarp.energy_strategy.
- PEN Heating, PEN DHW, PEN Elec
Non-renewable Primary Energy used for operation of heating, domestic hotwater and for consumed electricity; specific values per square meter floor area;
- Total PEN
Sum of PEN Heating, DHW and Elec;
- CO2 Heating, CO2 DHW, CO2 Elec
CO2 emissions for the operation of heating, domestic hot water and for consumed electricity; specific values per squre meter floor area;
- Total CO2
Sum of CO2 Heating, DHW and Elec
- Heating - Fuel Costs, DHW - Fuels Costs:
Costs for the fuel (energy carrier) for operation of heating respectively domestic hot water.
- Electricity - Costs:
Costs of consumed electricity (if the energy carrier for DHW or Heating is electricity, electricity usage is not included here but included under Heating/DHW - Fuel Costs)
- Year used for lookup of cost factors:
Simulation year which was used to lookup several factors, see the description of Inputs above